From: Joey Castillo Date: Sun, 8 Jun 2025 13:47:31 +0000 (-0600) Subject: temperature display: long press to toggle units X-Git-Url: https://git.earman.xyz/?a=commitdiff_plain;h=9459b7d01f2a29013d7536c61ffee3ba16101121;p=sensor-watch.git temperature display: long press to toggle units --- diff --git a/watch-faces/sensor/temperature_display_face.c b/watch-faces/sensor/temperature_display_face.c index 161b22d..819240e 100644 --- a/watch-faces/sensor/temperature_display_face.c +++ b/watch-faces/sensor/temperature_display_face.c @@ -53,7 +53,7 @@ bool temperature_display_face_loop(movement_event_t event, void *context) { (void) context; watch_date_time_t date_time = watch_rtc_get_date_time(); switch (event.event_type) { - case EVENT_ALARM_BUTTON_DOWN: + case EVENT_ALARM_LONG_PRESS: movement_set_use_imperial_units(!movement_use_imperial_units()); _temperature_display_face_update_display(movement_use_imperial_units()); break;